Flooded Evaporator Together With Working Of A Flooded Evaporator

Flooded Evaporator:


The flooded evaporator is a device which is used to command together with hold the required score of liquid refrigerant inwards evaporator together with this evaporator is used to shop the liquid refrigerant amongst the manage of a drum. Flooded evaporator helps to run the refrigeration arrangement cleanly past times maintaining the constant liquid level.

Main parts of a flooded evaporator:



Drum:

This is used equally the storage tank together with furnish the required vapour refrigerant to the compressor.

Evaporator:

This is used to uncovering the score of the liquid refrigerant.

Suction pipe:

 This is used to furnish the vapour of refrigerant into the compressor.

Compressor:

This is used to compress the vapour refrigerant.

Float chamber:

It is used to uncovering the score of liquid refrigerant together with helps to furnish the required refrigerant to the drum amongst the manage of float arranged inwards it.

Float:

This is used to furnish together with cease the liquid refrigerant piece of occupation into into the drum.

Inlet pipe:

This is used to furnish the required refrigerant together with controls amongst the manage of command valve.

Working of a flooded Evaporator:

The flooded evaporator consists of a drum which is placed equally shown inwards the figure, the drum is used to shop the liquid refrigerant past times maintaining the required score of liquid refrigerant inwards the evaporator. The flooded evaporator drum is likewise used to split the liquid refrigerant from vapour refrigerant.
The liquid refrigerant is stored inwards the bottom of the drum together with vapour refrigerant flows to the compressor through the suction pipage shown inwards the figure.
Due to the furnish of rut to the liquid refrigerant, it converts into vapourization together with moves over the overstep of the drum together with enters into the suction pipage for farther compression process. due to vaporization of the liquid refrigerant, the score inwards the drum gets decreased past times this the float sleeping accommodation attached to it likewise decreases the score of the liquid refrigerant, past times this, the float arranged inwards the sleeping accommodation larn decreased together with helps to furnish the liquid refrigerant inwards to the float sleeping accommodation together with farther transferred into the drum later increasing the score of fluid the float arranged inwards the sleeping accommodation reaches the furnish business of the liquid refrigerant together with cease the supply.